Description The ISIS-4 Safety Control Unit can monitor up to 4 ISIS safety switches. This easy to install, 35mm DIN Rail mounting housing provides 2 x safety and 1 x auxiliary output contacts (4A / 230V ac). Indicator LED’s in the ISIS-4 lid show the number of gates that have been selected, gate status, power and run.
A DIP switch located beneath the lid is used to select the number of active safety switches (note: The selector switch and number of safety switches must match or the control unit will not operate.) The coded magnetic safety switches provide a reliable, tamper resistant and cost effective method of monitoring machinery guarding where regular access is required. Approved by TUV to Category 3, the ISIS safety system is suitable for many applications including packing machinery and food processing environments. Approvals 
Dimensions 
Dimensions in MM Technical Specification
| Specifications | | Supply Voltage | 24V ac/dc, 110V ac, 230V ac | | Power Consumption | 6VA | | Output contacts | 2xNO Safety Contacts, 1xNC Auxiliary Contact | | Safety Contact Switching | 4A@230V ac or 30V dc | | Safety Switch Inputs | 4, (use ISIS-E to add more inputs) | | E'Stop Input | Dual Channel, cross monitored | | Mounting | 35 mm DIN Rail | | IP Rating | Housing IP40, Terminal IP20c | | Indication | Guard selected and status LED's | | Features | Emergency stop and safety switch control in one unit | | Approvals | TUV Category 3 | | UL 508 Industrial Control Equipment | | CE | | Safety Related Data | | | PL In accordance with EN ISO 13849-1 | PL-e Cat 3 | | SIL CL In accordance with EN IEC62061 | SIL 3 | | PFHd In accordance with EN IEC62061 | 5.63 x 10-8 | | PFH | 3.37 x 10-8 | | B10d | 2000000 | | MTTFd | High > 100 years
Based on usage rate of 360 days/year, 24 hours/day, 10 operations/hour | | TM (Mission Time) | 20 Years | | DC | 99% | | SFF | 99.4% |
|