FM1 Safety Control Unit

Description

The FM1 is the master control module for all F-Series Safety Systems. It contains the regulated power supply, 2 safety contact outputs (PGC), external/internal relay monitoring circuit and system indication along with the input for one safety switch sensor and it’s indication outputs.

The FM1 and one Mechan Safety Switch Sensor are all that is required for a system monitoring one guard. Simply clip the FM1 into a suitable control cabinet, fit the safety switch sensor to the guard and connect the supply and the volt free control contacts as shown in the installation guide.

For larger systems use the FX1 & FX2 Extender units with the FM1.

Approvals
 
   

TUV-CE Logo


Dimensions

FM1 Dimension 

 

 

 

 

 

 

 

 
Dimensions in MM

Technical Specification

Specifications
Control CategoryEN 954 CAT 4
Power Consumption100mA / 6VA
Supply Voltage24Vdc; 24Vac, 110Vac, 230Vac
Output Safety Contacts2 x N/O
Safety Contact Switching2A@230V ac or 30Vdc
Safety Switch Inputs1; Use FX1 & FX2 to built larger systems. scrip
IndicationPower, Run & Fault LED's; Gate Status LED & Volt F
Dimensions105 x 90 x 59mm
Mounting35mm DIN Rail
IP RatingHousing IP40; Terminals IP20
FeaturesExternal fault monitoring circuit, Manual monitore
ApprovalsTUV Category 4
CE

 