Mechan Controls
Order Basket: Items=0 | View Basket >>  
 

FM1 Safety Control Unit

Description

The FM1 is the master control module for all F-Series Safety Systems. It contains the regulated power supply, 2 safety contact outputs (PGC), external/internal relay monitoring circuit and system indication along with the input for one safety switch sensor and it’s indication outputs.

The FM1 and one Mechan Safety Switch Sensor are all that is required for a system monitoring one guard. Simply clip the FM1 into a suitable control cabinet, fit the safety switch sensor to the guard and connect the supply and the volt free control contacts as shown in the installation guide.

For larger systems use the FX1 & FX2 Extender units with the FM1.

Approvals
 
   

TUV-CE Logo


Dimensions

FM1 Dimension 

 

 

 

 

 

 

 

 
Dimensions in MM

Technical Specification

Specifications
Supply Voltage24Vdc; 24Vac, 110Vac, 230Vac
Power Consumption100mA / 6VA
Output Safety Contacts2 x N/O
Safety Contact Switching2A@230V ac or 30Vdc
Safety Switch Inputs1, Use FX1 & FX2 to build larger systems.
IndicationPower, Run & Fault LED's; Gate Status LED & Volt Free contact
Dimensions105 x 90 x 59mm
Mounting35mm DIN Rail
IP RatingHousing IP40; Terminals IP20
FeaturesExternal fault monitoring circuit
Automatic or monitored manual reset 
CE
Safety Related Data 
PL In accordance with EN ISO 13849-1 PL-e Cat 4
SIL CL In accordance with EN IEC62061SIL 3
PFHd In accordance with EN IEC620616.0 x 10-9
PFH6.52 x 10-9
B10d2000000
MTTFd High > 100years
Based on usage rate of 360 days/year, 24 hours/day, 10 operations/hour
TM (Mission Time)20 Years
DC99%
SFF99.5%

 

View Larger Image
Add to Basket


DOWNLOADS:
Specifications>>
Installations Guide >>
Dimensional Drawings >>
<< Back