Description The CM1 is the master control module for all CODEX Safety Systems. It contains the regulated power supply, 2 safety contact outputs (PGC), external/internal relay monitoring circuit and system indication along with the input for one safety switch sensor and it’s indication outputs.
The CM1 and one Mechan Safety Switch Sensor are all that is required for a system monitoring one guard. Simply clip the CM1 into a suitable control cabinet, fit the safety switch sensor to the guard and connect the supply and the volt free control contacts as shown in the installation guide.
For larger systems use the CX1 & CX2 Extender units with the CM1. 
Dimensions
Dimensions in MM
Technical Specification
| Specifications | | Control Category | EN 954 CAT 4 | | Supply Voltage | 24Vdc; 24Vac, 110Vac, 230V | | Power Consupmtion | 100mA / 6VA | | Output Safety Contacts | 2 x N/O | | Safety Contact Switching | 2A@230Vac or 30Vdcgadw.c | | Safety Switch Inputs | 1, Use CX1 & CX2 to build larger systems | | Indication | Power, Run & Fault LED's; Gate Status LED & Volt F | | Dimensions | 105 x 90 x 59mm | | Mounting | 35mm DIN Rail | | IP Rating | Housing IP40; Terminals IP20c | | Features | External relay monitoringc | | Indication from each switch | | Unique coding available | | Electronic switching |
|