Mechan Controls
Order Basket: Items=0 | View Basket >>  
 

CM1 Safety Control Unit

Description

The CM1 is the master control module for all CODEX Safety Systems. It contains the regulated power supply, 2 safety contact outputs (PGC), external/internal relay monitoring circuit and system indication along with the input for one safety switch sensor and it’s indication outputs.

The CM1 and one Mechan Safety Switch Sensor are all that is required for a system monitoring one guard. Simply clip the CM1 into a suitable control cabinet, fit the safety switch sensor to the guard and connect the supply and the volt free control contacts as shown in the installation guide.

For larger systems use the CX1 & CX2 Extender units with the CM1.

ce-logo

Dimensions

CM1 Dimension 

 

 

 

 

 








Dimensions in MM

Technical Specification

Specifications
Control CategoryEN 954 CAT 4
Supply Voltage24Vdc; 24Vac, 110Vac, 230V
Power Consupmtion100mA / 6VA
Output Safety Contacts2 x N/O
Safety Contact Switching2A@230Vac or 30Vdcgadw.c
Safety Switch Inputs1, Use CX1 & CX2 to build larger systems
IndicationPower, Run & Fault LED's; Gate Status LED & Volt F
Dimensions105 x 90 x 59mm
Mounting35mm DIN Rail
IP RatingHousing IP40; Terminals IP20c
FeaturesExternal relay monitoringc
Indication from each switch
Unique coding available
Electronic switching

 